The Mitsubishi MR-J2-200CT Go to product viewer dialog for this item.
Alarms on the MR-J2-200CT are generally categorized into three distinct groups based on severity and origin: mitsubishi mr-j2-200ct alarm list
Often signifies a ground fault in the motor output (U, V, W) or a failure in the transistor power module. The Mitsubishi MR-J2-200CT Go to product viewer dialog
| Alarm Code | Alarm Name | Main Causes | Corrective Action | |------------|------------|-------------|--------------------| | | Undervoltage | Power supply voltage drop, instantaneous power failure | Check power supply input (200VAC ±10%), measure voltage at L11, L21 | | 12 | Memory error (EEPROM) | Defective EEPROM, excessive write cycles | Replace servo amplifier, reset parameters to factory default | | 13 | Clock error | CPU board malfunction, noise interference | Cycle power, replace amplifier if recurring | | 15 | Memory error (RAM) | Internal RAM fault | Replace servo amplifier | | 16 | Encoder initial communication error | Encoder cable break, connector loose, noise | Check CN2 wiring, shield grounding, cable length (<20m) | | 17 | Board error | CPU board failure | Replace amplifier | | 20 | Absolute position lost (ABS) | Battery voltage low (for absolute encoder) | Replace battery (ER6/CR2), perform homing again | | 24 | Main circuit error | Overvoltage, insufficient regenerative resistor | Check regenerative resistor value/connection, deceleration torque | | 25 | Overvoltage | Regenerative voltage too high | Increase deceleration time, add external regenerative resistor | | 30 | Regenerative error | Regenerative resistor overload or open circuit | Check resistor value (e.g., 30Ω/100W), cooling, deceleration pattern | | 31 | Overspeed | Command frequency too high, encoder fault | Limit speed command, check encoder feedback | | 32 | Overcurrent | Short circuit in motor winding, IGBT failure | Check motor insulation resistance, replace amplifier | | 33 | Overload | Excessive torque, locked rotor, mechanical binding | Reduce load, check coupling/gearbox, increase motor size | | 35 | Command pulse frequency error | Pulse input rate exceeds 500kpps | Reduce command speed, check controller output | | 37 | Parameter error | Invalid parameter setting (e.g., wrong motor ID) | Verify all parameters (PA, PB, PC groups) | | 38 | Serial communication timeout | Communication break with controller (RS-422) | Check wiring at CN3, baud rate, protocol (Mitsubishi format) | | 45 | Main circuit overvoltage (instantaneous) | Surge voltage, poor power quality | Install line reactor, check mains stability | | 50 | Overload 2 (electronic thermal) | Continuous high RMS current | Reduce duty cycle, improve cooling | | 52 | Excessive deviation | Position error > parameter setting | Increase torque limit, reduce acceleration, check encoder | | 88 | Emergency stop | External EMG signal activated | Release emergency stop switch, check EMG input circuit | Usually after incorrect manual entry
| Alarm Code | Alarm Name | Description & Cause | Corrective Action | | :--- | :--- | :--- | :--- | | | Parameter Error | Invalid or out-of-range parameter value set. Usually after incorrect manual entry. | Initialize all parameters to factory defaults (set parameter Pa19 = 'FACT'). Re-enter custom values carefully. | | AL.38 | Combination Error | Motor and amplifier do not match. MR-J2-200CT requires HC-MF, HC-SF, or HC-RF series motor of 200W–2000W range. | Check motor model number. Replace with compatible motor. Update rotary switch settings (SW1) for motor type. | | AL.39 | Absolute Position Counter Error | Malfunction in absolute position counter memory (EEPROM). | Execute “Absolute position clear” using MR Configurator. If recurring, replace encoder. | | AL.42 | Servo Emergency Stop Triggered | EMG input (CN1 pin 15) is open or forced low. | Wire EMG to +24V via NC contact. Check emergency stop button state. Remove external EMG signal if not used. | | AL.43 | Software Limit Error | Commanded position exceeds software limit set in parameters (Pa14/Pa15). | Adjust target position. Widen software limits. Disable limits temporarily for testing. | | AL.44 | Overload (Low Speed) | High current at near-zero speed. Motor stalled or brake engaged. | Release mechanical brake. Increase torque limit if absolutely necessary. Check for foreign object in load. |
AL 92: Battery cable disconnection (Absolute position system). AL 96: Home position setting error. AL E0: Excessive regeneration warning (Approaching AL 30). AL E1: Overload warning (Approaching AL 50). Resetting Alarms